Why a cold snap catches so many homes out
Through a mild October, your heating sits quietly doing very little. Then the forecast turns, the temperature drops six degrees overnight, and suddenly every radiator, pump and boiler in the house is working flat out. That is when the weak points show themselves: the radiator that never quite warmed at the top, the boiler that has not been looked at since last winter, the thermostat battery clinging on by hope alone.
The good news is that almost everything that goes wrong in a cold snap can be prevented in an hour or two on a quiet weekend. Do the work now, while the sun is still doing some of the heating for you, and you will spend the cold weeks warm rather than waiting on a call-out list.
Book your boiler service before the rush
An annual service is the single best thing you can do for a gas boiler. A registered engineer will check the burner, heat exchanger, flue and seals, measure combustion, and confirm there are no leaks. Crucially, they will usually spot a worn part before it fails. Late summer and early autumn are the quietest months for heating engineers; by the time the first frost arrives, diaries fill up fast.
While the boiler is being looked at, ask them to check the condensate pipe. This is the plastic pipe that carries acidic water away from a condensing boiler, and in a hard frost it can freeze solid, causing the boiler to lock out and stop entirely. Where possible it should run internally to a drain. If it must go outside, lag it properly with foam insulation and keep the run as short and as steep as you can.
Also learn to read the pressure gauge on your boiler. When the system is cold it should usually sit between 1 and 1.5 bar. Below 1 bar, the boiler may refuse to fire. Top it up slowly through the filling loop, then close the valve fully and note the reading. If you find yourself topping it up every few weeks, there is a leak or a faulty part, and it wants attention.
Bleed the radiators and check for cold spots
Trapped air is the most common reason a radiator stays lukewarm. Let the system cool completely, then work around the house with a radiator key and a cloth.
- Open the bleed valve at the top of the radiator a quarter turn. You will hear a hiss of escaping air.
- As soon as a steady trickle of water appears, close the valve firmly. Do not over-tighten.
- Start with the radiators furthest from the boiler and work back towards it.
- Check the boiler pressure afterwards, as bleeding lowers it.
Pay attention to where a radiator is cold. Cold at the top means air, which bleeding fixes. Cold at the bottom, with warmth along the top, usually means sludge and debris settled in the system. That needs a proper flush, and a magnetic filter fitted on the return pipe will help keep it clean afterwards.
Give the controls a proper test
Turn the room thermostat up a few degrees and listen for the boiler to fire. If nothing happens, check the batteries in wireless thermostats and radiator valves first, as these are the usual culprits. A room temperature of 18 to 21°C suits most households, and every degree lower saves a little on the bill.
Set the thermostatic radiator valves sensibly: around 3 in bedrooms, 4 in living rooms, and 1 or 2 in spare rooms where you only want frost protection. If you have a boiler in a garage, outbuilding or cold loft, make sure a frost stat is fitted and working. Finally, adjust your programmer. Heating that came on at 7am in September may need to start twenty minutes earlier in January to bring the house up to temperature.
Keep the heat in and the air moving
Lag any exposed hot water pipes in the loft and around the cylinder, and check that loft insulation has not been disturbed or compressed. Close curtains at dusk and open them during daylight to let the sun help. Move furniture and tuck away long curtains so they are not blocking radiators.
Do not seal a home up completely, though. Some background ventilation keeps condensation and damp at bay, which matters far more in winter when windows stay shut. Trickle vents and extractor fans are there for a reason.
Your pre-winter checklist
- Boiler serviced and condensate pipe lagged.
- System pressure checked at 1 to 1.5 bar when cold.
- Every radiator bled, with cold spots noted.
- Thermostat, programmer and valve batteries tested.
- TRVs set room by room and the timer adjusted.
- Pipes lagged, insulation checked, radiators left clear.
An afternoon spent on these jobs will see you through the coldest week of the year with a warm house and a quiet mind.